Removing Ammonium Chloride Salt from Titanium (TSR#20-B-085)

Customer was looking for a new cleaning process to improve their cleaning performance, eliminate manual cleaning, eliminate process steps.

Before
After
Cleaning Trial Type
Abrasive Cleaning
Industry
Substrate
Titanium
Description of Part(s)
6” x 6” titanium-grade 2 plates
Machine Used
Dry Blast Cabinet
Type of Blasting
Contained
Post Cleaning
De-ionized water rinse and air pressure dried
Soil
Rust/Oxides
Recommendation
We recommend using ARMEX™ Maintenance Formula Blast Media –with a #4 Performance Nozzle at a blasting pressure 25 psi for the cleaning of a mixture of metal oxides and ammonium chloride salt.